#region_cd;scc;poll;pcec;ceff;reff;rpen;sic;mact;app;rep;facility_id;unit_id;rel_point_id;process_id;unused;unused_and_comments
10003;;"NOX";;23.0;100.0;100.0;;;Y;A;"588311";;;;2016-01-01 00:00:00;!""! 2018 docket comment: DE Emission cap to all NOx sources at the Delaware City Refinery""
23003;;"NOX";;80.5195;100.0;100.0;;;Y;R;"8199911";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  MCCAIN FOODS USA INC - EASTON""
23003;;"SO2";;44.4444;100.0;100.0;;;Y;R;"8199911";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  MCCAIN FOODS USA INC - EASTON""
23003;;;;100.0;100.0;100.0;;;Y;R;"5660811";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  MCCAIN FOODS USA INC - TATERMEAL""
23005;;"NOX";;44.4444;100.0;100.0;;;Y;R;"5823511";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  FPL ENERGY WYMAN LLC""
23007;;"SO2";;77.7778;100.0;100.0;;;Y;R;"7764711";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  project at facility-level, switching to natural gas: VERSO PAPER - ANDROSCOGGIN MILL""
23009;;"SO2";;70.0599;100.0;100.0;;;Y;R;"8387311";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  project at facility-level, switching to natural gas: VERSO BUCKSPORT, LLC""
23011;;"SO2";;75.2475;100.0;100.0;;;Y;R;"5691611";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  HUHTAMAKI INC - WATERVILLE""
23013;;"SO2";;73.1664;100.0;100.0;;;Y;R;"5692011";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  FMC BIOPOLYMER""
23023;;"NOX";;69.3878;100.0;100.0;;;Y;R;"8386911";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  BATH IRON WORKS - BATH FACILITY""
23023;;"SO2";;79.1667;100.0;100.0;;;Y;R;"8386911";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  BATH IRON WORKS - BATH FACILITY""
23025;;"SO2";;86.755;100.0;100.0;;;Y;R;"5253911";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  project at facility-level, switching to natural gas: MADISON PAPER INDUSTRIES""
23025;;"SO2";;73.8994;100.0;100.0;;;Y;R;"8200111";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  project at facility-level, switching to natural gas: SAPPI - SOMERSET""
23029;;"SO2";;79.5918;100.0;100.0;;;Y;R;"5974211";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  project at facility-level, switching to natural gas: WOODLAND PULP LLC""
23031;;;;100.0;100.0;100.0;;;Y;R;"5987911";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  MAINE ENERGY RECOVERY CO""
24043;30500606;"NOX";;5.699947337;100.0;100.0;;;Y;R;"7931411";"88032213";"84222312";"119453914";2016-09-09 00:00:00;!""! 2011v6.0 CoST packet: CD Darin: Pollutant Reductions section of CD settlement webpage (http://www2.epa.gov/enforcement/holcim-us-inc-settlement) specifies a emission reduction of 92 tons, will be proportion across all relevant processes""
24043;30500606;"NOX";;5.699947337;100.0;100.0;;;Y;R;"7931411";"88032213";"84222312";"119454014";2016-09-09 00:00:00;!""! 2011v6.0 CoST packet: CD Darin: Pollutant Reductions section of CD settlement webpage (http://www2.epa.gov/enforcement/holcim-us-inc-settlement) specifies a emission reduction of 92 tons, will be proportion across all relevant processes""
24043;30500606;"NOX";;5.699947337;100.0;100.0;;;Y;R;"7931411";"88032213";"84222412";"119453914";2016-09-09 00:00:00;!""! 2011v6.0 CoST packet: CD Darin: Pollutant Reductions section of CD settlement webpage (http://www2.epa.gov/enforcement/holcim-us-inc-settlement) specifies a emission reduction of 92 tons, will be proportion across all relevant processes""
24043;30500606;"NOX";;5.699947337;100.0;100.0;;;Y;R;"7931411";"88032213";"84222412";"119454014";2016-09-09 00:00:00;!""! 2011v6.0 CoST packet: CD Darin: Pollutant Reductions section of CD settlement webpage (http://www2.epa.gov/enforcement/holcim-us-inc-settlement) specifies a emission reduction of 92 tons, will be proportion across all relevant processes""
24043;30500606;"SO2";;42.82543607;100.0;100.0;;;Y;R;"7931411";"88032213";"84222312";"119453914";2016-09-09 00:00:00;!""! 2011v6.0 CoST packet: CD Darin: Pollutant Reductions section of CD settlement webpage (http://www2.epa.gov/enforcement/holcim-us-inc-settlement) specifies a emission reduction of 230 tons, will be proportion across all relevant processes""
24043;30500606;"SO2";;42.82543607;100.0;100.0;;;Y;R;"7931411";"88032213";"84222312";"119454014";2016-09-09 00:00:00;!""! 2011v6.0 CoST packet: CD Darin: Pollutant Reductions section of CD settlement webpage (http://www2.epa.gov/enforcement/holcim-us-inc-settlement) specifies a emission reduction of 230 tons, will be proportion across all relevant processes""
24043;30500606;"SO2";;42.82543607;100.0;100.0;;;Y;R;"7931411";"88032213";"84222412";"119453914";2016-09-09 00:00:00;!""! 2011v6.0 CoST packet: CD Darin: Pollutant Reductions section of CD settlement webpage (http://www2.epa.gov/enforcement/holcim-us-inc-settlement) specifies a emission reduction of 230 tons, will be proportion across all relevant processes""
24043;30500606;"SO2";;42.82543607;100.0;100.0;;;Y;R;"7931411";"88032213";"84222412";"119454014";2016-09-09 00:00:00;!""! 2011v6.0 CoST packet: CD Darin: Pollutant Reductions section of CD settlement webpage (http://www2.epa.gov/enforcement/holcim-us-inc-settlement) specifies a emission reduction of 230 tons, will be proportion across all relevant processes""
25000;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2016-05-01 00:00:00;!""! 2018 docket comment: MA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
25000;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2016-05-01 00:00:00;!""! 2018 docket comment: MA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
25000;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2016-05-01 00:00:00;!""! 2018 docket comment: MA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
25027;;"NOX";;85.0;100.0;100.0;;;Y;R;"7259211";"87674413";;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=12/31/2010: Saint Gobain: Control Device= oxyfuel -plant= STGOBAINCONTAINERS""
25027;;"NOX";;85.0;100.0;100.0;;;Y;R;"7259211";"87674513";;;2015-12-31 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=12/31/2015: Saint Gobain: Control Device= oxyfuel -plant= STGOBAINCONTAINERS""
25027;;"PM10-PRI";;99.0;100.0;100.0;;;Y;R;"7259211";"87674413";;;2015-12-31 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=12/31/2015: Saint Gobain: Control Device= ESP -plant= STGOBAINCONTAINERS""
25027;;"PM10-PRI";;99.0;100.0;100.0;;;Y;R;"7259211";"87674513";;;2015-12-31 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=12/31/2015: Saint Gobain: Control Device= ESP -plant= STGOBAINCONTAINERS""
25027;;"PM25-PRI";;95.0;100.0;100.0;;;Y;R;"7259211";"87674413";;;2015-12-31 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=12/31/2015: Saint Gobain: Control Device= ESP -plant= STGOBAINCONTAINERS""
25027;;"PM25-PRI";;95.0;100.0;100.0;;;Y;R;"7259211";"87674513";;;2015-12-31 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=12/31/2015: Saint Gobain: Control Device= ESP -plant= STGOBAINCONTAINERS""
25027;;"SO2";;85.0;100.0;100.0;;;Y;R;"7259211";"87674413";;;2015-12-31 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=12/31/2015: Saint Gobain: Control Device= Semi-dry Scrubber or CCSS -plant= STGOBAINCONTAINERS""
25027;;"SO2";;85.0;100.0;100.0;;;Y;R;"7259211";"87674513";;;2015-12-31 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=12/31/2015: Saint Gobain: Control Device= Semi-dry Scrubber or CCSS -plant= STGOBAINCONTAINERS""
33009;;"NOX";;20.35458813;100.0;100.0;;;Y;R;"7868311";"3382613";;;2017-01-01 00:00:00;!""! 2011v6.0 CoST packet: CSAPR PT comments v1:  NH docket 3854, 72% reduction in CSAPR SCR, SNCR yields 54.68tpy target""
33019;;"NOX";;34.2748902;100.0;100.0;;;Y;R;"7853911";"2824413";;;2017-01-01 00:00:00;!""! 2011v6.0 CoST packet: CSAPR PT comments v1:  NH docket 3854, 72% reduction in CSAPR SCR, SNCR yields 50.52tpy target""
34000;30630007;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Indus /Re-refining Lube Oils & Greases /Finished Product Storage Tank""
34000;30630007;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Indus /Re-refining Lube Oils & Greases /Finished Product Storage Tank""
34000;30630007;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Indus /Re-refining Lube Oils & Greases /Finished Product Storage Tank""
34000;30630007;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Indus /Re-refining Lube Oils & Greases /Finished Product Storage Tank""
34000;30630007;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Indus /Re-refining Lube Oils & Greases /Finished Product Storage Tank""
34000;30630007;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Indus /Re-refining Lube Oils & Greases /Finished Product Storage Tank""
34000;30630007;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Indus /Re-refining Lube Oils & Greases /Finished Product Storage Tank""
34000;30630007;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Indus /Re-refining Lube Oils & Greases /Finished Product Storage Tank""
34000;30630007;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Indus /Re-refining Lube Oils & Greases /Finished Product Storage Tank""
34000;40301101;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13: Standing Loss (67000 Bbl Tank)""
34000;40301101;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13: Standing Loss (67000 Bbl Tank)""
34000;40301101;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13: Standing Loss (67000 Bbl Tank)""
34000;40301101;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13: Standing Loss (67000 Bbl Tank)""
34000;40301101;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13: Standing Loss (67000 Bbl Tank)""
34000;40301101;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13: Standing Loss (67000 Bbl Tank)""
34000;40301101;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13: Standing Loss (67000 Bbl Tank)""
34000;40301101;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13: Standing Loss (67000 Bbl Tank)""
34000;40301101;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13: Standing Loss (67000 Bbl Tank)""
34000;40301108;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13/10/7: Withdrawal Loss (250000 BblTank)""
34000;40301108;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13/10/7: Withdrawal Loss (250000 BblTank)""
34000;40301108;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13/10/7: Withdrawal Loss (250000 BblTank)""
34000;40301108;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13/10/7: Withdrawal Loss (250000 BblTank)""
34000;40301108;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13/10/7: Withdrawal Loss (250000 BblTank)""
34000;40301108;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13/10/7: Withdrawal Loss (250000 BblTank)""
34000;40301108;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13/10/7: Withdrawal Loss (250000 BblTank)""
34000;40301108;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13/10/7: Withdrawal Loss (250000 BblTank)""
34000;40301108;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline RVP 13/10/7: Withdrawal Loss (250000 BblTank)""
34000;40301115;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (67000 Bbl Tank)""
34000;40301115;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (67000 Bbl Tank)""
34000;40301115;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (67000 Bbl Tank)""
34000;40301115;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (67000 Bbl Tank)""
34000;40301115;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (67000 Bbl Tank)""
34000;40301115;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (67000 Bbl Tank)""
34000;40301115;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (67000 Bbl Tank)""
34000;40301115;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (67000 Bbl Tank)""
34000;40301115;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (67000 Bbl Tank)""
34000;40301116;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (250000 Bbl Tank)""
34000;40301116;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (250000 Bbl Tank)""
34000;40301116;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (250000 Bbl Tank)""
34000;40301116;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (250000 Bbl Tank)""
34000;40301116;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (250000 Bbl Tank)""
34000;40301116;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (250000 Bbl Tank)""
34000;40301116;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (250000 Bbl Tank)""
34000;40301116;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (250000 Bbl Tank)""
34000;40301116;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Distillate Fuel #2: Standing Loss (250000 Bbl Tank)""
34000;40301117;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Crude Oil RVP 5: Withdrawal Loss""
34000;40301117;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Crude Oil RVP 5: Withdrawal Loss""
34000;40301117;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Crude Oil RVP 5: Withdrawal Loss""
34000;40301117;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Crude Oil RVP 5: Withdrawal Loss""
34000;40301117;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Crude Oil RVP 5: Withdrawal Loss""
34000;40301117;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Crude Oil RVP 5: Withdrawal Loss""
34000;40301117;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Crude Oil RVP 5: Withdrawal Loss""
34000;40301117;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Crude Oil RVP 5: Withdrawal Loss""
34000;40301117;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Crude Oil RVP 5: Withdrawal Loss""
34000;40301118;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Jet Naphtha (JP-4): Withdrawal Loss""
34000;40301118;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Jet Naphtha (JP-4): Withdrawal Loss""
34000;40301118;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Jet Naphtha (JP-4): Withdrawal Loss""
34000;40301118;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Jet Naphtha (JP-4): Withdrawal Loss""
34000;40301118;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Jet Naphtha (JP-4): Withdrawal Loss""
34000;40301118;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Jet Naphtha (JP-4): Withdrawal Loss""
34000;40301118;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Jet Naphtha (JP-4): Withdrawal Loss""
34000;40301118;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Jet Naphtha (JP-4): Withdrawal Loss""
34000;40301118;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Jet Naphtha (JP-4): Withdrawal Loss""
34000;40301150;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss - Internal""
34000;40301150;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss - Internal""
34000;40301150;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss - Internal""
34000;40301150;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss - Internal""
34000;40301150;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss - Internal""
34000;40301150;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss - Internal""
34000;40301150;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss - Internal""
34000;40301150;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss - Internal""
34000;40301150;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss - Internal""
34000;40301151;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline: Standing Loss - Internal""
34000;40301151;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline: Standing Loss - Internal""
34000;40301151;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline: Standing Loss - Internal""
34000;40301151;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline: Standing Loss - Internal""
34000;40301151;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline: Standing Loss - Internal""
34000;40301151;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline: Standing Loss - Internal""
34000;40301151;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline: Standing Loss - Internal""
34000;40301151;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline: Standing Loss - Internal""
34000;40301151;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Gasoline: Standing Loss - Internal""
34000;40301197;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Withdrawal Loss""
34000;40301197;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Withdrawal Loss""
34000;40301197;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Withdrawal Loss""
34000;40301197;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Withdrawal Loss""
34000;40301197;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Withdrawal Loss""
34000;40301197;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Withdrawal Loss""
34000;40301197;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Withdrawal Loss""
34000;40301197;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Withdrawal Loss""
34000;40301197;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Withdrawal Loss""
34000;40301198;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (67000 Bbl Tank)""
34000;40301198;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (67000 Bbl Tank)""
34000;40301198;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (67000 Bbl Tank)""
34000;40301198;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (67000 Bbl Tank)""
34000;40301198;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (67000 Bbl Tank)""
34000;40301198;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (67000 Bbl Tank)""
34000;40301198;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (67000 Bbl Tank)""
34000;40301198;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (67000 Bbl Tank)""
34000;40301198;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (67000 Bbl Tank)""
34000;40301199;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (250000 Bbl Tank)""
34000;40301199;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (250000 Bbl Tank)""
34000;40301199;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (250000 Bbl Tank)""
34000;40301199;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (250000 Bbl Tank)""
34000;40301199;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (250000 Bbl Tank)""
34000;40301199;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (250000 Bbl Tank)""
34000;40301199;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (250000 Bbl Tank)""
34000;40301199;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (250000 Bbl Tank)""
34000;40301199;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Floating Roof Tanks /Specify Liquid: Standing Loss (250000 Bbl Tank)""
34000;40388801;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Fugitive Emissions /Specify in Comments Field""
34000;40388801;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Fugitive Emissions /Specify in Comments Field""
34000;40388801;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Fugitive Emissions /Specify in Comments Field""
34000;40388801;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Fugitive Emissions /Specify in Comments Field""
34000;40388801;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Fugitive Emissions /Specify in Comments Field""
34000;40388801;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Fugitive Emissions /Specify in Comments Field""
34000;40388801;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Fugitive Emissions /Specify in Comments Field""
34000;40388801;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Fugitive Emissions /Specify in Comments Field""
34000;40388801;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Refinery /Fugitive Emissions /Specify in Comments Field""
34000;40400113;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss (250000 BBL) - Floating Roof Tank""
34000;40400113;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss (250000 BBL) - Floating Roof Tank""
34000;40400113;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss (250000 BBL) - Floating Roof Tank""
34000;40400113;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss (250000 BBL) - Floating Roof Tank""
34000;40400113;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss (250000 BBL) - Floating Roof Tank""
34000;40400113;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss (250000 BBL) - Floating Roof Tank""
34000;40400113;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss (250000 BBL) - Floating Roof Tank""
34000;40400113;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss (250000 BBL) - Floating Roof Tank""
34000;40400113;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss (250000 BBL) - Floating Roof Tank""
34000;40400130;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - External Floating Roof w/ Primary Seal""
34000;40400130;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - External Floating Roof w/ Primary Seal""
34000;40400130;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - External Floating Roof w/ Primary Seal""
34000;40400130;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - External Floating Roof w/ Primary Seal""
34000;40400130;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - External Floating Roof w/ Primary Seal""
34000;40400130;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - External Floating Roof w/ Primary Seal""
34000;40400130;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - External Floating Roof w/ Primary Seal""
34000;40400130;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - External Floating Roof w/ Primary Seal""
34000;40400130;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - External Floating Roof w/ Primary Seal""
34000;40400131;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400131;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400131;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400131;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400131;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400131;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400131;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400131;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400131;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400132;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400132;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400132;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400132;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400132;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400132;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400132;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400132;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400132;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Ext. Floating Roof w/ Primary Seal""
34000;40400149;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: External Floating Roof (Primary/Secondary Seal)""
34000;40400149;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: External Floating Roof (Primary/Secondary Seal)""
34000;40400149;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: External Floating Roof (Primary/Secondary Seal)""
34000;40400149;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: External Floating Roof (Primary/Secondary Seal)""
34000;40400149;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: External Floating Roof (Primary/Secondary Seal)""
34000;40400149;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: External Floating Roof (Primary/Secondary Seal)""
34000;40400149;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: External Floating Roof (Primary/Secondary Seal)""
34000;40400149;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: External Floating Roof (Primary/Secondary Seal)""
34000;40400149;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: External Floating Roof (Primary/Secondary Seal)""
34000;40400150;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Miscellaneous Losses/Leaks: Loading Racks""
34000;40400150;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Miscellaneous Losses/Leaks: Loading Racks""
34000;40400150;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Miscellaneous Losses/Leaks: Loading Racks""
34000;40400150;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Miscellaneous Losses/Leaks: Loading Racks""
34000;40400150;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Miscellaneous Losses/Leaks: Loading Racks""
34000;40400150;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Miscellaneous Losses/Leaks: Loading Racks""
34000;40400150;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Miscellaneous Losses/Leaks: Loading Racks""
34000;40400150;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Miscellaneous Losses/Leaks: Loading Racks""
34000;40400150;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Miscellaneous Losses/Leaks: Loading Racks""
34000;40400160;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - Internal Floating Roof w/ Primary Seal""
34000;40400160;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - Internal Floating Roof w/ Primary Seal""
34000;40400160;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - Internal Floating Roof w/ Primary Seal""
34000;40400160;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - Internal Floating Roof w/ Primary Seal""
34000;40400160;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - Internal Floating Roof w/ Primary Seal""
34000;40400160;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - Internal Floating Roof w/ Primary Seal""
34000;40400160;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - Internal Floating Roof w/ Primary Seal""
34000;40400160;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - Internal Floating Roof w/ Primary Seal""
34000;40400160;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Standing Loss - Internal Floating Roof w/ Primary Seal""
34000;40400162;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Primary Seal""
34000;40400162;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Primary Seal""
34000;40400162;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Primary Seal""
34000;40400162;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Primary Seal""
34000;40400162;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Primary Seal""
34000;40400162;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Primary Seal""
34000;40400162;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Primary Seal""
34000;40400162;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Primary Seal""
34000;40400162;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Primary Seal""
34000;40400172;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400172;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400172;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400172;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400172;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400172;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400172;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400172;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400172;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400178;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13/10/7: Withdrawal Loss - Int. Float Roof (Pri/Sec Seal)""
34000;40400178;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13/10/7: Withdrawal Loss - Int. Float Roof (Pri/Sec Seal)""
34000;40400178;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13/10/7: Withdrawal Loss - Int. Float Roof (Pri/Sec Seal)""
34000;40400178;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13/10/7: Withdrawal Loss - Int. Float Roof (Pri/Sec Seal)""
34000;40400178;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13/10/7: Withdrawal Loss - Int. Float Roof (Pri/Sec Seal)""
34000;40400178;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13/10/7: Withdrawal Loss - Int. Float Roof (Pri/Sec Seal)""
34000;40400178;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13/10/7: Withdrawal Loss - Int. Float Roof (Pri/Sec Seal)""
34000;40400178;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13/10/7: Withdrawal Loss - Int. Float Roof (Pri/Sec Seal)""
34000;40400178;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Gasoline RVP 13/10/7: Withdrawal Loss - Int. Float Roof (Pri/Sec Seal)""
34000;40400179;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400179;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400179;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400179;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400179;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400179;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400179;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400179;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400179;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400199;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /See Comment **""
34000;40400199;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /See Comment **""
34000;40400199;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /See Comment **""
34000;40400199;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /See Comment **""
34000;40400199;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /See Comment **""
34000;40400199;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /See Comment **""
34000;40400199;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /See Comment **""
34000;40400199;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /See Comment **""
34000;40400199;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Terminals /See Comment **""
34000;40400271;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 13: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400271;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 13: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400271;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 13: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400271;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 13: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400271;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 13: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400271;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 13: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400271;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 13: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400271;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 13: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400271;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 13: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400272;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400272;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400272;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400272;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400272;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400272;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400272;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400272;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400272;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Gasoline RVP 10: Standing Loss - Int. Floating Roof w/ Secondary Seal""
34000;40400279;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400279;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400279;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400279;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400279;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400279;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400279;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400279;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400279;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Bulk Plants /Specify Liquid: Internal Floating Roof (Primary/Secondary Seal)""
34000;40400401;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Breathing Loss""
34000;40400401;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Breathing Loss""
34000;40400401;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Breathing Loss""
34000;40400401;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Breathing Loss""
34000;40400401;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Breathing Loss""
34000;40400401;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Breathing Loss""
34000;40400401;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Breathing Loss""
34000;40400401;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Breathing Loss""
34000;40400401;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Breathing Loss""
34000;40400402;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Working Loss""
34000;40400402;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Working Loss""
34000;40400402;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Working Loss""
34000;40400402;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Working Loss""
34000;40400402;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Working Loss""
34000;40400402;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Working Loss""
34000;40400402;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Working Loss""
34000;40400402;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Working Loss""
34000;40400402;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 13: Working Loss""
34000;40400406;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 7: Working Loss""
34000;40400406;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 7: Working Loss""
34000;40400406;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 7: Working Loss""
34000;40400406;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 7: Working Loss""
34000;40400406;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 7: Working Loss""
34000;40400406;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 7: Working Loss""
34000;40400406;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 7: Working Loss""
34000;40400406;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 7: Working Loss""
34000;40400406;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Gasoline RVP 7: Working Loss""
34000;40400497;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Specify Liquid: Breathing Loss""
34000;40400497;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Specify Liquid: Breathing Loss""
34000;40400497;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Specify Liquid: Breathing Loss""
34000;40400497;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Specify Liquid: Breathing Loss""
34000;40400497;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Specify Liquid: Breathing Loss""
34000;40400497;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Specify Liquid: Breathing Loss""
34000;40400497;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Specify Liquid: Breathing Loss""
34000;40400497;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Specify Liquid: Breathing Loss""
34000;40400497;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Prod Stor-Underground Tanks /Specify Liquid: Breathing Loss""
34000;40600503;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Trans & Marketg /Pipeline Transp - All Products /Pump Station""
34000;40600503;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Trans & Marketg /Pipeline Transp - All Products /Pump Station""
34000;40600503;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Trans & Marketg /Pipeline Transp - All Products /Pump Station""
34000;40600503;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Trans & Marketg /Pipeline Transp - All Products /Pump Station""
34000;40600503;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Trans & Marketg /Pipeline Transp - All Products /Pump Station""
34000;40600503;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Trans & Marketg /Pipeline Transp - All Products /Pump Station""
34000;40600503;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Trans & Marketg /Pipeline Transp - All Products /Pump Station""
34000;40600503;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Trans & Marketg /Pipeline Transp - All Products /Pump Station""
34000;40600503;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Petrol Trans & Marketg /Pipeline Transp - All Products /Pump Station""
34000;40715802;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Methanol: Withdrawal Loss""
34000;40715802;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Methanol: Withdrawal Loss""
34000;40715802;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Methanol: Withdrawal Loss""
34000;40715802;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Methanol: Withdrawal Loss""
34000;40715802;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Methanol: Withdrawal Loss""
34000;40715802;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Methanol: Withdrawal Loss""
34000;40715802;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Methanol: Withdrawal Loss""
34000;40715802;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Methanol: Withdrawal Loss""
34000;40715802;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Methanol: Withdrawal Loss""
34000;40729698;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Specify In Comments: Working Loss""
34000;40729698;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Specify In Comments: Working Loss""
34000;40729698;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Specify In Comments: Working Loss""
34000;40729698;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Specify In Comments: Working Loss""
34000;40729698;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Specify In Comments: Working Loss""
34000;40729698;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Specify In Comments: Working Loss""
34000;40729698;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Specify In Comments: Working Loss""
34000;40729698;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Specify In Comments: Working Loss""
34000;40729698;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Floating Roof Tanks - Specify In Comments: Working Loss""
34000;40799997;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Specify in Comments""
34000;40799997;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Specify in Comments""
34000;40799997;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Specify in Comments""
34000;40799997;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Specify in Comments""
34000;40799997;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Specify in Comments""
34000;40799997;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Specify in Comments""
34000;40799997;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Specify in Comments""
34000;40799997;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Specify in Comments""
34000;40799997;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Specify in Comments""
34000;40799999;"VOC";;0.86;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Other Not Classified""
34000;40799999;"VOC";;1.72;100.0;100.0;;;Y;R;;;;;2013-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Other Not Classified""
34000;40799999;"VOC";;2.58;100.0;100.0;;;Y;R;;;;;2014-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Other Not Classified""
34000;40799999;"VOC";;3.44;100.0;100.0;;;Y;R;;;;;2015-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Other Not Classified""
34000;40799999;"VOC";;4.3;100.0;100.0;;;Y;R;;;;;2016-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Other Not Classified""
34000;40799999;"VOC";;5.16;100.0;100.0;;;Y;R;;;;;2017-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Other Not Classified""
34000;40799999;"VOC";;6.02;100.0;100.0;;;Y;R;;;;;2018-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Other Not Classified""
34000;40799999;"VOC";;6.88;100.0;100.0;;;Y;R;;;;;2019-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Other Not Classified""
34000;40799999;"VOC";;7.74;100.0;100.0;;;Y;R;;;;;2020-01-01 00:00:00;!""! 2018 docket comment: NJ Storage Tank Rules Organic Chem Storage - Miscellaneous /Other Not Classified""
34011;10200603;"NOX";;45.0;100.0;100.0;;;Y;R;"7392811";;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Glass Rule Nipro Glass Americas""
34011;30501401;"NOX";;45.0;100.0;100.0;;;Y;R;"12804611";;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Glass Rule Gerresheimer Moulded Glass""
34011;30501402;"NOX";;45.0;100.0;100.0;;;Y;R;"7392811";;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Glass Rule Nipro Glass Americas""
34011;30501404;"NOX";;45.0;100.0;100.0;;;Y;R;"7311811";;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Glass Rule Gerresheimer Glass  Inc""
34011;30501406;"NOX";;45.0;100.0;100.0;;;Y;R;"7392811";;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Glass Rule Nipro Glass Americas""
34011;30501499;"NOX";;45.0;100.0;100.0;;;Y;R;"7392811";;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Glass Rule Nipro Glass Americas""
34011;30599999;"NOX";;45.0;100.0;100.0;;;Y;R;"7462011";;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Glass Rule Ardagh Glass Packaging Inc.""
34011;39900601;"NOX";;45.0;100.0;100.0;;;Y;R;"7461411";;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Glass Rule Durand Glass Manufacturing Company  Inc.""
34015;;"PM10-PRI";;58.35;100.0;100.0;;;Y;A;"7201311";;;;2013-12-01 00:00:00;!""! 2011v6.0 CoST packet: OECA:  Facility Group=VALERO: OECA consent decree information compiled by Josh 3/24/09: Combined PM emissions over multiple facilities reduced by 526 tons per year.""
34015;;"PM25-PRI";;58.35;100.0;100.0;;;Y;A;"7201311";;;;2013-12-01 00:00:00;!""! 2011v6.0 CoST packet: OECA:  Facility Group=VALERO: OECA consent decree information compiled by Josh 3/24/09: Combined PM emissions over multiple facilities reduced by 526 tons per year.""
34033;30501402;"NOX";;45.0;100.0;100.0;;;Y;R;"7480011";;;;2012-01-01 00:00:00;!""! 2018 docket comment: NJ Glass Rule Anchor Glass Container Corporation""
34039;;"NOX";;0.07;100.0;100.0;;;Y;A;"7903711";;;;2013-12-01 00:00:00;!""! 2011v6.0 CoST packet: OECA:  Facility Group=CONOCO: OECA consent decree information compiled by Josh 3/24/09: Combined NOx emissions over multiple facilities reduced by 10000 tons per year.""
36001;;"NOX";;12.48984565;100.0;100.0;;;Y;R;"8105211";"4818313";;;2013-01-01 00:00:00;!""! 2011v6.0 CoST packet: CSAPR PT comments v1:  ISIS controls -replacing wet kilns with new, controlled kilns:  LafargeN.A. OVERRIDE LaFarge Consent decree (50%): per call w/ Elineth 1/12/11: leave existing plant, but add controls. email 1/13/11, 5:50pm: docketID=3857, target=4309tpy""
36001;;"SO2";;74.46185998;100.0;100.0;;;Y;R;"8105211";"4818313";;;2013-01-01 00:00:00;!""! 2011v6.0 CoST packet: CSAPR PT comments v1:  ISIS controls -replacing wet kilns with new, controlled kilns:  LafargeN.A. OVERRIDE LaFarge Consent decree (90%): per call w/ Elineth 1/12/11: leave existing plant, but add controls. email 1/13/11, 5:50pm: docketID=3857, target=2444tpy""
36113;;"NOX";;50.0;100.0;100.0;;;Y;A;"8325311";"133713";;;2017-01-01 00:00:00;!""! 2011v6.0 CoST packet: Regional Haze:  Lehigh Northeast Cement, kiln specific""
36113;;"NOX";;50.0;100.0;100.0;;;Y;A;;"8325311";"133713";;2017-01-01 00:00:00;!""! 2018 docket comment: Regional Haze Cement Lehigh Northeast Cement  kiln specific""
37181;;"NOX";;40.0;100.0;100.0;;;Y;R;"8010411";"4036413";"69101812";;2013-12-31 00:00:00;!""! 2018 docket comment: OECA Settlements NCDAQ Revise control factor of 70% that used by EPA for 2018 EMP, Version 1, to 40% to reflect consent decree requirements in facilities' operating permit. NOx emissions in 2011 = 366 TPY.""
37181;;"NOX";;80.0;100.0;100.0;;;Y;R;"8010411";"4036013";"69101912";;2016-12-31 00:00:00;!""! 2018 docket comment: OECA Settlements NCDAQ Revise control factor of 85% that used by EPA for 2018 EMP, Version 1, to 80% to reflect consent decree requirements in facilities' operating permit. NOx emissions in 2011 = 250 TPY.""
42000;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: PA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
42000;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: PA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
42000;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2012-01-01 00:00:00;!""! 2018 docket comment: PA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
42045;;"NOX";;82.49;100.0;100.0;;;Y;A;"4724811";;;;2013-12-01 00:00:00;!""! 2011v6.0 CoST packet: OECA:  Facility Group=SUNOCO: OECA consent decree information compiled by Josh 3/24/09: Combined NOx emissions over multiple facilities reduced by 4500 tons per year.""
42045;;"PM10-PRI";;76.29;100.0;100.0;;;Y;A;"4724811";;;;2013-12-01 00:00:00;!""! 2011v6.0 CoST packet: OECA:  Facility Group=SUNOCO: OECA consent decree information compiled by Josh 3/24/09: Combined PM emissionsover multiple facilities reduced by 300 tons per year.""
42045;;"PM25-PRI";;76.29;100.0;100.0;;;Y;A;"4724811";;;;2013-12-01 00:00:00;!""! 2011v6.0 CoST packet: OECA:  Facility Group=SUNOCO: OECA consent decree information compiled by Josh 3/24/09: Combined PM emissionsover multiple facilities reduced by 300 tons per year.""
42077;;"NOX";;50.0;100.0;100.0;;;Y;R;"6621911";"18982113";;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=1/1/2011: LaFarge: Control Device= SCNR -plant= LafargeN.A.""
42077;;"SO2";;70.0;100.0;100.0;;;Y;R;"6621911";"18982113";;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=1/1/2011: LaFarge: Control Device= DAA -plant= LafargeN.A.""
42083;;"NOX";;70.0;100.0;100.0;;;Y;R;"6532611";"19110713";;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=12/31/2010: Saint Gobain: Control Device= OEAS -plant= SAINTGOBAINCONTAINERS/PORTALLEGANYBO""
42083;;"NOX";;70.0;100.0;100.0;;;Y;R;"6532611";"19110913";;;2013-12-31 00:00:00;!""! 2011v6.0 CoST packet: LaFarge:  cdate=12/31/2013: Saint Gobain: Control Device= OEAS -plant= SAINTGOBAINCONTAINERS/PORTALLEGANYBO""
42101;;"NOX";;21.38;100.0;100.0;;;Y;A;"6652211";;;;2013-12-01 00:00:00;!""! 2011v6.0 CoST packet: OECA:  Facility Group=SUNOCO: OECA consent decree information compiled by Josh 3/24/09: Combined NOx emissions over multiple facilities reduced by 4500 tons per year.""
42101;;"PM10-PRI";;52.86;100.0;100.0;;;Y;A;"6652211";;;;2013-12-01 00:00:00;!""! 2011v6.0 CoST packet: OECA:  Facility Group=SUNOCO: OECA consent decree information compiled by Josh 3/24/09: Combined PM emissionsover multiple facilities reduced by 300 tons per year.""
42101;;"PM25-PRI";;52.86;100.0;100.0;;;Y;A;"6652211";;;;2013-12-01 00:00:00;!""! 2011v6.0 CoST packet: OECA:  Facility Group=SUNOCO: OECA consent decree information compiled by Josh 3/24/09: Combined PM emissionsover multiple facilities reduced by 300 tons per year.""
51019;;"NOX";;100.0;100.0;100.0;;;Y;R;"4183311";"32655713";"31206312";"402214";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  GP Big Island LLC""
51019;;"SO2";;79.70530998;100.0;100.0;;;Y;R;"4183311";"32655713";;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: CSAPR PT comments v1:  cdate=12/31/2011: GPBigIslandLLC: Unit is subject to a BART permit limit requiring a wet scrubber by 01/01/2012 and a limit of no more than 219 tpy SO2.: 12/2, 1:57pm email from Doris McLeod (VA DEQ): docketID=3840""
51019;;"SO2";;100.0;100.0;100.0;;;Y;R;"4183311";"32655713";"31206312";"402214";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  GP Big Island LLC""
51036;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
51036;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
51036;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
51041;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
51041;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
51041;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
51085;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
51085;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
51085;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
51087;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
51087;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
51087;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
51121;;"SO2";;10.89566359;100.0;100.0;;;Y;R;"5748511";"21782713";;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: CSAPR PT comments v1:  cdate=12/31/2008: VirginiaTech: Voluntary installation of dry lime scrubbing in 2008: 12/2, 1:57pm email from Doris McLeod (VA DEQ): docketID=3840, target=243tpy""
51149;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
51149;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
51149;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
51510;;;;100.0;100.0;100.0;;;Y;R;"6922811";;;;2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  GenOn Potomac River Limited Liability Corp""
51570;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
51570;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
51570;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
51580;;"SO2";;15.0;100.0;100.0;;;Y;A;"5798711";;;;2017-01-01 00:00:00;!""! 2011v6.0 CoST packet: Regional Haze:  Meadwestvaco Packaging plant - Covington. Emissions were tiny for the activated carbon facility, so applying to the packaging plant.""
51670;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
51670;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
51670;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
51670;;"NH3";;96.4245;100.0;100.0;;;Y;R;"5769011";"20375813";"19638912";"76698514";2019-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  :""
51670;;"NH3";;73.7364;100.0;100.0;;;Y;R;"5769011";"20379913";"19636712";"76696814";2019-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  :""
51670;;"NH3";;75.9373;100.0;100.0;;;Y;R;"5769011";"20380313";"19640012";"76696614";2019-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  :""
51670;;"NH3";;76.6558;100.0;100.0;;;Y;R;"5769011";"20382913";"19635412";"76696414";2019-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  :""
51670;;"NH3";;0.2558;100.0;100.0;;;Y;R;"5769011";"20384513";"19635212";"76698414";2019-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  :""
51670;;"NH3";;89.3748;100.0;100.0;;;Y;R;"5769011";"20384613";"19643012";"76698314";2019-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  :""
51670;;"NOX";;90.0662;100.0;100.0;;;Y;R;"5769011";"20380213";"19634612";"76696714";2019-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  :""
51670;;"NOX";;91.994;100.0;100.0;;;Y;R;"5769011";"20384513";"19635212";"76698414";2019-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  :""
51670;;"NOX";;86.8926;100.0;100.0;;;Y;R;"5769011";"20375713";"19635012";"76696514";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Honeywell International Inc - Hopewell""
51670;;"NOX";;89.8143;100.0;100.0;;;Y;R;"5769011";"20380313";"19640012";"76696614";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Honeywell International Inc - Hopewell""
51670;;"NOX";;89.8464;100.0;100.0;;;Y;R;"5769011";"20382913";"19635412";"76696414";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Honeywell International Inc - Hopewell""
51670;;"NOX";;91.4662;100.0;100.0;;;Y;R;"5769011";"20384613";"19643012";"76698314";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Honeywell International Inc - Hopewell""
51670;;"NOX";;90.6219;100.0;100.0;;;Y;R;"5769011";"20384713";"19639312";"76698214";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Honeywell International Inc - Hopewell""
51670;;"NOX";;92.2653;100.0;100.0;;;Y;R;"5769011";"20384813";"19636512";"76698114";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Honeywell International Inc - Hopewell""
51730;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
51730;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
51730;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
51760;40200701;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive Application""
51760;40200706;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: Solvent Mixing""
51760;40200710;"VOC";;64.4;100.0;100.0;;;Y;R;;;;;2014-03-01 00:00:00;!""! 2018 docket comment: VA Adhesives Rule: Surface Coating Application  General /Adhesive: General""
51820;;"NOX";;100.0;100.0;100.0;;;Y;R;"4958111";"30858413";"29524612";"1838014";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Invista  - Waynesboro""
51820;;"NOX";;100.0;100.0;100.0;;;Y;R;"4958111";"30858513";"29524612";"1837614";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Invista  - Waynesboro""
51820;;"NOX";;100.0;100.0;100.0;;;Y;R;"4958111";"30858913";"29524612";"1836714";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Invista  - Waynesboro""
51820;;"SO2";;100.0;100.0;100.0;;;Y;R;"4958111";"30858413";"29524612";"1838014";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Invista  - Waynesboro""
51820;;"SO2";;100.0;100.0;100.0;;;Y;R;"4958111";"30858513";"29524612";"1837614";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Invista  - Waynesboro""
51820;;"SO2";;100.0;100.0;100.0;;;Y;R;"4958111";"30858913";"29524612";"1836714";2012-01-01 00:00:00;!""! 2011v6.0 CoST packet: ST comments v1:  Invista  - Waynesboro""
42095;30500606;"NOX";;32.41085932;100.0;100.0;;;Y;R;"6651211";"105508513";"109040712";"149782514";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42095;30500606;"NOX";;21.34775179;100.0;100.0;;;Y;R;"3881611";"37152313";"35403112";"13676314";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42095;30500606;"NOX";;18.60629993;100.0;100.0;;;Y;R;"3881611";"37154213";"35403112";"13673914";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42095;30500623;"NOX";;30.65747065;100.0;100.0;;;Y;R;"6582211";"89390113";"85388912";"121118214";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42011;10200603;"NOX";;6.99154827;100.0;100.0;;;Y;R;"6597611";"17356513";"62054512";"17221614";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42011;30500606;"NOX";;6.99154827;100.0;100.0;;;Y;R;"6597611";"17356513";"62054512";"17221714";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42011;30500606;"NOX";;4.270983118;100.0;100.0;;;Y;R;"6597611";"17356313";"62054612";"17222214";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42011;10200603;"NOX";;4.270983118;100.0;100.0;;;Y;R;"6597611";"17356313";"62054612";"17222514";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42007;30501402;"NOX";;25.76413941;100.0;100.0;;;Y;R;"3853811";"37814413";"36065812";"13629614";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42065;30501402;"NOX";;39.97558528;100.0;100.0;;;Y;R;"3020711";"38361413";"36632012";"13427214";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42083;30501402;"NOX";;45.31252484;100.0;100.0;;;Y;R;"3025211";"38189913";"36473912";"13943214";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42083;30501402;"NOX";;23.07560019;100.0;100.0;;;Y;R;"3025211";"38190113";"36474112";"13942814";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42039;30501403;"NOX";;61.44828239;100.0;100.0;;;Y;R;"6603511";"19025613";"18484812";"16928714";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42041;30501403;"NOX";;68.32570591;100.0;100.0;;;Y;R;"6463511";"18725313";"18169212";"16871614";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42041;30501403;"NOX";;66.96075378;100.0;100.0;;;Y;R;"6463511";"18725413";"18170012";"16871414";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42045;30501403;"NOX";;12.43698099;100.0;100.0;;;Y;R;"5456011";"27328013";"26222412";"13776014";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42021;20300201;"NOX";;67.89012909;100.0;100.0;;;Y;R;"3674311";"37064613";"35323312";"13517714";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42021;20300201;"NOX";;54.43003945;100.0;100.0;;;Y;R;"3674311";"37064713";"35323412";"13517614";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42021;20200202;"NOX";;47.23269441;100.0;100.0;;;Y;R;"3674311";"37064913";"35323612";"13517414";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42021;20300201;"NOX";;9.64121054;100.0;100.0;;;Y;R;"3674311";"94863913";"91658512";"129901614";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42001;20200201;"NOX";;70.05412789;100.0;100.0;;;Y;R;"4697611";"28155513";"26999612";"17152714";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42001;20200201;"NOX";;22.1041845;100.0;100.0;;;Y;R;"4697611";"28155713";"26999412";"17152514";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42055;20200201;"NOX";;64.32666475;100.0;100.0;;;Y;R;"3768511";"37871413";"36127012";"14054314";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42009;20200201;"NOX";;18.21725944;100.0;100.0;;;Y;R;"3855611";"37806413";"36057212";"14014014";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42009;20200201;"NOX";;14.36924227;100.0;100.0;;;Y;R;"3855611";"37806313";"36057012";"14014114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42009;20200201;"NOX";;4.237734682;100.0;100.0;;;Y;R;"3855611";"67439913";"62046712";"93018614";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42007;20300201;"NOX";;37.61847149;100.0;100.0;;;Y;R;"3854311";"67437313";"62044312";"93015714";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42105;20200202;"NOX";;79.24867025;100.0;100.0;;;Y;R;"4720011";"27922413";"26805312";"15360214";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42105;20200202;"NOX";;82.46026526;100.0;100.0;;;Y;R;"4720011";"27922213";"26805512";"15360414";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42035;20200202;"NOX";;0.210299058;100.0;100.0;;;Y;R;"6661711";"17769213";"17277712";"16993514";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42035;20200202;"NOX";;13.35953616;100.0;100.0;;;Y;R;"6661711";"17768813";"17277312";"16993914";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42035;20200202;"NOX";;37.15087662;100.0;100.0;;;Y;R;"6661711";"17769913";"17276812";"17037214";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42105;20300201;"NOX";;50.85256799;100.0;100.0;;;Y;R;"4719811";"27924913";"26808112";"15364214";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42105;20200202;"NOX";;86.05647721;100.0;100.0;;;Y;R;"4719911";"27923813";"26806412";"15361914";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42105;20200202;"NOX";;14.82841336;100.0;100.0;;;Y;R;"4719911";"27924713";"26807212";"15361014";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42105;20200202;"NOX";;33.32851468;100.0;100.0;;;Y;R;"4719911";"27924513";"26807512";"15361214";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42105;20300201;"NOX";;18.73741126;100.0;100.0;;;Y;R;"4719911";"67561613";"62180712";"93177114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42129;20300201;"NOX";;49.38714863;100.0;100.0;;;Y;R;"3189411";"38717313";"36999112";"15129714";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42129;20300201;"NOX";;50.22975258;100.0;100.0;;;Y;R;"3189411";"38715813";"36998512";"15131214";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42065;20300201;"NOX";;83.43020007;100.0;100.0;;;Y;R;"3021111";"38359513";"36629812";"14300914";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42129;20300201;"NOX";;64.20373985;100.0;100.0;;;Y;R;"3189311";"38717813";"36999512";"15132114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42129;20300201;"NOX";;65.41897849;100.0;100.0;;;Y;R;"3189311";"38717713";"36999412";"15132214";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42129;20100202;"NOX";;74.70492727;100.0;100.0;;;Y;R;"3189311";"38717613";"36999212";"15132314";2017-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42125;20200202;"NOX";;74.79103495;100.0;100.0;;;Y;R;"3895611";"37441913";"35714412";"93202514";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42125;20200202;"NOX";;49.15857104;100.0;100.0;;;Y;R;"3895611";"37441613";"35714412";"93202614";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42125;20200202;"NOX";;61.71914799;100.0;100.0;;;Y;R;"3895611";"37442013";"35714412";"14709514";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42005;20300201;"NOX";;39.02051193;100.0;100.0;;;Y;R;"3866311";"37163513";"35415412";"13751414";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42005;20300201;"NOX";;39.48130839;100.0;100.0;;;Y;R;"3866311";"37163613";"35415012";"13751314";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42005;20300201;"NOX";;74.48882897;100.0;100.0;;;Y;R;"3866311";"37163713";"35415112";"13751214";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42005;20300201;"NOX";;44.39951959;100.0;100.0;;;Y;R;"3866311";"37163413";"35415212";"13751514";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42005;20300201;"NOX";;55.54478948;100.0;100.0;;;Y;R;"3866211";"37163913";"35415912";"13752214";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42005;20300201;"NOX";;7.869759562;100.0;100.0;;;Y;R;"3866211";"37164013";"35415712";"13752114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42085;20200202;"NOX";;44.0736435;100.0;100.0;;;Y;R;"3123311";"38152813";"36415512";"13662914";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42085;20200202;"NOX";;4.991526506;100.0;100.0;;;Y;R;"3123311";"38152913";"36416112";"13662814";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42085;20200202;"NOX";;1.417921794;100.0;100.0;;;Y;R;"3123311";"38153013";"36415112";"13662714";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42085;20200202;"NOX";;22.7210702;100.0;100.0;;;Y;R;"3123311";"38153213";"36415712";"13662514";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42085;20200202;"NOX";;25.78255516;100.0;100.0;;;Y;R;"3123311";"38153313";"36414912";"13662414";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42085;20200202;"NOX";;2.977443465;100.0;100.0;;;Y;R;"3123311";"38152613";"36415612";"13663114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42085;20200202;"NOX";;7.25043758;100.0;100.0;;;Y;R;"3123311";"38152413";"36415312";"13663314";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42085;20200202;"NOX";;37.60468385;100.0;100.0;;;Y;R;"3123311";"38152313";"36415012";"13663414";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42085;20200202;"NOX";;18.12447435;100.0;100.0;;;Y;R;"3123311";"38152213";"36416012";"13663514";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42085;20200202;"NOX";;6.958231852;100.0;100.0;;;Y;R;"3123311";"38152113";"36415412";"13663614";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42129;20200201;"NOX";;67.16558284;100.0;100.0;;;Y;R;"3189211";"38718213";"37000212";"15133614";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42059;20200202;"NOX";;35.4107609;100.0;100.0;;;Y;R;"3747111";"37859713";"62087012";"13846414";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42059;20200202;"NOX";;45.62620712;100.0;100.0;;;Y;R;"3747111";"37859513";"62087112";"13846614";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42059;20200202;"NOX";;56.78987673;100.0;100.0;;;Y;R;"3747111";"37859013";"62087212";"13847114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42059;20200202;"NOX";;58.28591821;100.0;100.0;;;Y;R;"3747111";"37859113";"62087312";"13847014";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42059;20200202;"NOX";;98.59826074;100.0;100.0;;;Y;R;"3747111";"37859813";"62087512";"13846314";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42021;20200201;"NOX";;33.06307032;100.0;100.0;;;Y;R;"3674211";"37065413";"35324112";"13517814";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42021;20200201;"NOX";;42.0649953;100.0;100.0;;;Y;R;"3674211";"37065113";"35323812";"13518114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42021;20200201;"NOX";;47.18897617;100.0;100.0;;;Y;R;"3674211";"37065313";"35324012";"13517914";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42021;20200201;"NOX";;41.85676972;100.0;100.0;;;Y;R;"3674211";"37065213";"35323912";"13518014";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42067;20200201;"NOX";;50.77420864;100.0;100.0;;;Y;R;"3022011";"38355713";"36626712";"14297214";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42067;20200201;"NOX";;57.47470472;100.0;100.0;;;Y;R;"3022011";"38355813";"36626412";"14297114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42067;20200201;"NOX";;57.47470612;100.0;100.0;;;Y;R;"3022011";"38356113";"36626012";"14296814";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42067;20200201;"NOX";;54.81405893;100.0;100.0;;;Y;R;"3022011";"38355513";"36626112";"13989314";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42051;20200201;"NOX";;2.530494453;100.0;100.0;;;Y;R;"3767411";"37875713";"36131212";"14146614";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42011;20200201;"NOX";;56.66734834;100.0;100.0;;;Y;R;"3857611";"37796213";"36048812";"14094814";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42011;20200201;"NOX";;46.99533859;100.0;100.0;;;Y;R;"3857611";"37796013";"36048412";"14095014";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42011;20200201;"NOX";;50.9138913;100.0;100.0;;;Y;R;"3857611";"37795913";"36048512";"14095114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42011;20200201;"NOX";;50.35361324;100.0;100.0;;;Y;R;"3857611";"37796113";"36048712";"14094914";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42011;20200201;"NOX";;44.26752649;100.0;100.0;;;Y;R;"3857511";"37796313";"36048912";"17160914";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42011;20200201;"NOX";;51.97292508;100.0;100.0;;;Y;R;"3857511";"37796513";"36049112";"14095314";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42043;20200201;"NOX";;54.00812329;100.0;100.0;;;Y;R;"6465411";"18716713";"18161612";"14057414";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42043;20200201;"NOX";;57.38780461;100.0;100.0;;;Y;R;"6465411";"18717013";"18161712";"14057114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42043;20200201;"NOX";;47.72510824;100.0;100.0;;;Y;R;"6465411";"18716913";"18161512";"14057214";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42043;20200201;"NOX";;49.47215861;100.0;100.0;;;Y;R;"6465411";"18716813";"18161412";"14057314";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42071;20200202;"NOX";;82.06500228;100.0;100.0;;;Y;R;"3864011";"37179913";"35429612";"13471814";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42071;20200202;"NOX";;64.73437369;100.0;100.0;;;Y;R;"3864011";"37179413";"35429412";"13472314";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42071;20200202;"NOX";;62.91610089;100.0;100.0;;;Y;R;"3864011";"37179813";"35429512";"13471914";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42071;20200202;"NOX";;67.9686981;100.0;100.0;;;Y;R;"3864011";"37180013";"35429912";"13471714";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42071;20200202;"NOX";;44.01482562;100.0;100.0;;;Y;R;"3864011";"37179713";"35429712";"13472014";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42071;20200202;"NOX";;60.66971351;100.0;100.0;;;Y;R;"3864011";"37179613";"35429812";"13472114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42099;20200201;"NOX";;47.55038662;100.0;100.0;;;Y;R;"3873111";"37779013";"36032412";"14323014";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42099;20200201;"NOX";;52.93928142;100.0;100.0;;;Y;R;"3873111";"37778913";"36032312";"14323114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42037;20200201;"NOX";;70.25915325;100.0;100.0;;;Y;R;"6602711";"19029113";"18490112";"16938914";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42081;20200201;"NOX";;68.32839778;100.0;100.0;;;Y;R;"5450911";"27549413";"26441112";"13858014";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
42081;20200201;"NOX";;68.68131977;100.0;100.0;;;Y;R;"5450911";"27549313";"26441312";"13858114";2017-01-01 00:00:00;!"" ! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16""
09003;50100101;"NOX";;25.0;100.0;100.0;;;Y;R;"588711";"46157913";"43830012";"48243314";2018-01-01 00:00:00;!""! CT RCSA-174-38 Revisions; per Paul Bodner 7/29/16""
09003;50100101;"NOX";;0;100.0;100.0;;;Y;R;"588711";"46158013";"43829912";"48243114";2018-01-01 00:00:00;!""! CT RCSA-174-38 Revisions; per Paul Bodner 7/29/16""
09001;50100105;"NOX";;25.0;100.0;100.0;;;Y;R;"754411";"46285513";"43960612";"47337814";2018-01-01 00:00:00;!""! CT RCSA-174-38 Revisions; per Paul Bodner 7/29/16""
09001;50100105;"NOX";;25.0;100.0;100.0;;;Y;R;"754411";"46285613";"43961212";"47337714";2018-01-01 00:00:00;!""! CT RCSA-174-38 Revisions; per Paul Bodner 7/29/16""
09001;50100105;"NOX";;25.0;100.0;100.0;;;Y;R;"754411";"46285713";"43961112";"47337514";2018-01-01 00:00:00;!""! CT RCSA-174-38 Revisions; per Paul Bodner 7/29/16""
09011;50100102;"NOX";;15.25423729;100.0;100.0;;;Y;R;"754611";"46284313";"43960112";"48248314";2018-01-01 00:00:00;!""! CT RCSA-174-38 Revisions; per Paul Bodner 7/29/16""
09011;50100102;"NOX";;15.25423729;100.0;100.0;;;Y;R;"754611";"46284413";"43960112";"48248214";2018-01-01 00:00:00;!""! CT RCSA-174-38 Revisions; per Paul Bodner 7/29/16""
09011;50100105;"NOX";;10.71428571;100.0;100.0;;;Y;R;"8501611";"961813";"96623812";"48266714";2018-01-01 00:00:00;!""! CT RCSA-174-38 Revisions; per Paul Bodner 7/29/16""
09011;50100105;"NOX";;10.71428571;100.0;100.0;;;Y;R;"8501611";"962013";"885812";"48266314";2018-01-01 00:00:00;!""! CT RCSA-174-38 Revisions; per Paul Bodner 7/29/16""
42021;20300201;"NOX";;78.89958683;100.0;100.0;;;Y;R;"3674311";"37064613";"35323312";"13517714";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42021;20300201;"NOX";;63.25673085;100.0;100.0;;;Y;R;"3674311";"37064713";"35323412";"13517614";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42021;20200202;"NOX";;54.89222253;100.0;100.0;;;Y;R;"3674311";"37064913";"35323612";"13517414";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42021;20300201;"NOX";;11.20468525;100.0;100.0;;;Y;R;"3674311";"94863913";"91658512";"129901614";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42001;20200201;"NOX";;80.67881457;100.0;100.0;;;Y;R;"4697611";"28155513";"26999612";"17152714";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42001;20200201;"NOX";;25.45659273;100.0;100.0;;;Y;R;"4697611";"28155713";"26999412";"17152514";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42055;20200201;"NOX";;74.08270168;100.0;100.0;;;Y;R;"3768511";"37871413";"36127012";"14054314";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42009;20200201;"NOX";;20.98016121;100.0;100.0;;;Y;R;"3855611";"37806413";"36057212";"14014014";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42009;20200201;"NOX";;16.5485385;100.0;100.0;;;Y;R;"3855611";"37806313";"36057012";"14014114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42009;20200201;"NOX";;4.88044632;100.0;100.0;;;Y;R;"3855611";"67439913";"62046712";"93018614";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42007;20300201;"NOX";;43.71890137;100.0;100.0;;;Y;R;"3854311";"67437313";"62044312";"93015714";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42105;20200202;"NOX";;92.10009502;100.0;100.0;;;Y;R;"4720011";"27922413";"26805312";"15360214";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42105;20200202;"NOX";;95.83250093;100.0;100.0;;;Y;R;"4720011";"27922213";"26805512";"15360414";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42035;20200202;"NOX";;0.244402375;100.0;100.0;;;Y;R;"6661711";"17769213";"17277712";"16993514";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42035;20200202;"NOX";;15.52599616;100.0;100.0;;;Y;R;"6661711";"17768813";"17277312";"16993914";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42035;20200202;"NOX";;43.1754786;100.0;100.0;;;Y;R;"6661711";"17769913";"17276812";"17037214";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42105;20300201;"NOX";;59.09911585;100.0;100.0;;;Y;R;"4719811";"27924913";"26808112";"15364214";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42105;20200202;"NOX";;100.0118955;100.0;100.0;;;Y;R;"4719911";"27923813";"26806412";"15361914";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42105;20200202;"NOX";;17.23307502;100.0;100.0;;;Y;R;"4719911";"27924713";"26807212";"15361014";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42105;20200202;"NOX";;38.73326024;100.0;100.0;;;Y;R;"4719911";"27924513";"26807512";"15361214";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42105;20300201;"NOX";;21.77597872;100.0;100.0;;;Y;R;"4719911";"67561613";"62180712";"93177114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42129;20300201;"NOX";;57.39605557;100.0;100.0;;;Y;R;"3189411";"38717313";"36999112";"15129714";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42129;20300201;"NOX";;58.37530107;100.0;100.0;;;Y;R;"3189411";"38715813";"36998512";"15131214";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42065;20300201;"NOX";;96.959726;100.0;100.0;;;Y;R;"3021111";"38359513";"36629812";"14300914";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42129;20300201;"NOX";;74.61539129;100.0;100.0;;;Y;R;"3189311";"38717813";"36999512";"15132114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42129;20300201;"NOX";;76.0277001;100.0;100.0;;;Y;R;"3189311";"38717713";"36999412";"15132214";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42129;20100202;"NOX";;74.70492727;100.0;100.0;;;Y;R;"3189311";"38717613";"36999212";"15132314";2023-01-01 00:00:00;!""! PA RACT II: CE from max allowable NOx rate compared to 2011 NOx rate: Provided by PA DEP 7/8/16""
42125;20200202;"NOX";;86.91958368;100.0;100.0;;;Y;R;"3895611";"37441913";"35714412";"93202514";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42125;20200202;"NOX";;57.1304105;100.0;100.0;;;Y;R;"3895611";"37441613";"35714412";"93202614";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42125;20200202;"NOX";;71.72788358;100.0;100.0;;;Y;R;"3895611";"37442013";"35714412";"14709514";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42005;20300201;"NOX";;45.34830484;100.0;100.0;;;Y;R;"3866311";"37163513";"35415412";"13751414";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42005;20300201;"NOX";;45.88382673;100.0;100.0;;;Y;R;"3866311";"37163613";"35415012";"13751314";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42005;20300201;"NOX";;86.56837022;100.0;100.0;;;Y;R;"3866311";"37163713";"35415112";"13751214";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42005;20300201;"NOX";;51.59960363;100.0;100.0;;;Y;R;"3866311";"37163413";"35415212";"13751514";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42005;20300201;"NOX";;64.55225524;100.0;100.0;;;Y;R;"3866211";"37163913";"35415912";"13752214";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42005;20300201;"NOX";;9.145965492;100.0;100.0;;;Y;R;"3866211";"37164013";"35415712";"13752114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42085;20200202;"NOX";;51.22088157;100.0;100.0;;;Y;R;"3123311";"38152813";"36415512";"13662914";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42085;20200202;"NOX";;5.800981443;100.0;100.0;;;Y;R;"3123311";"38152913";"36416112";"13662814";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42085;20200202;"NOX";;1.64786023;100.0;100.0;;;Y;R;"3123311";"38153013";"36415112";"13662714";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42085;20200202;"NOX";;26.40565094;100.0;100.0;;;Y;R;"3123311";"38153213";"36415712";"13662514";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42085;20200202;"NOX";;29.96360409;100.0;100.0;;;Y;R;"3123311";"38153313";"36414912";"13662414";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42085;20200202;"NOX";;3.460282995;100.0;100.0;;;Y;R;"3123311";"38152613";"36415612";"13663114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42085;20200202;"NOX";;8.426210659;100.0;100.0;;;Y;R;"3123311";"38152413";"36415312";"13663314";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42085;20200202;"NOX";;43.70287784;100.0;100.0;;;Y;R;"3123311";"38152313";"36415012";"13663414";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42085;20200202;"NOX";;21.06364441;100.0;100.0;;;Y;R;"3123311";"38152213";"36416012";"13663514";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42085;20200202;"NOX";;8.086619153;100.0;100.0;;;Y;R;"3123311";"38152113";"36415412";"13663614";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42129;20200201;"NOX";;77.35218133;100.0;100.0;;;Y;R;"3189211";"38718213";"37000212";"15133614";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42059;20200202;"NOX";;41.15317561;100.0;100.0;;;Y;R;"3747111";"37859713";"62087012";"13846414";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42059;20200202;"NOX";;52.47624616;100.0;100.0;;;Y;R;"3747111";"37859513";"62087112";"13846614";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42059;20200202;"NOX";;65.31596069;100.0;100.0;;;Y;R;"3747111";"37859013";"62087212";"13847114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42059;20200202;"NOX";;67.03660866;100.0;100.0;;;Y;R;"3747111";"37859113";"62087312";"13847014";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42021;20200201;"NOX";;38.07754661;100.0;100.0;;;Y;R;"3674211";"37065413";"35324112";"13517814";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42021;20200201;"NOX";;48.4447392;100.0;100.0;;;Y;R;"3674211";"37065113";"35323812";"13518114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42021;20200201;"NOX";;54.34584332;100.0;100.0;;;Y;R;"3674211";"37065313";"35324012";"13517914";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42021;20200201;"NOX";;48.2049333;100.0;100.0;;;Y;R;"3674211";"37065213";"35323912";"13518014";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42067;20200201;"NOX";;58.47482636;100.0;100.0;;;Y;R;"3022011";"38355713";"36626712";"14297214";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42067;20200201;"NOX";;66.19154623;100.0;100.0;;;Y;R;"3022011";"38355813";"36626412";"14297114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42067;20200201;"NOX";;66.19154784;100.0;100.0;;;Y;R;"3022011";"38356113";"36626012";"14296814";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42067;20200201;"NOX";;63.12737635;100.0;100.0;;;Y;R;"3022011";"38355513";"36626112";"13989314";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42051;20200201;"NOX";;2.914279271;100.0;100.0;;;Y;R;"3767411";"37875713";"36131212";"14146614";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42011;20200201;"NOX";;65.26174297;100.0;100.0;;;Y;R;"3857611";"37796213";"36048812";"14094814";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42011;20200201;"NOX";;54.1228379;100.0;100.0;;;Y;R;"3857611";"37796013";"36048412";"14095014";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42011;20200201;"NOX";;58.63569384;100.0;100.0;;;Y;R;"3857611";"37795913";"36048512";"14095114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42011;20200201;"NOX";;57.99044179;100.0;100.0;;;Y;R;"3857611";"37796113";"36048712";"14094914";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42011;20200201;"NOX";;50.981315;100.0;100.0;;;Y;R;"3857511";"37796313";"36048912";"17160914";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42011;20200201;"NOX";;59.85534488;100.0;100.0;;;Y;R;"3857511";"37796513";"36049112";"14095314";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42043;20200201;"NOX";;62.19920932;100.0;100.0;;;Y;R;"6465411";"18716713";"18161612";"14057414";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42043;20200201;"NOX";;66.0914665;100.0;100.0;;;Y;R;"6465411";"18717013";"18161712";"14057114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42043;20200201;"NOX";;54.9632873;100.0;100.0;;;Y;R;"6465411";"18716913";"18161512";"14057214";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42043;20200201;"NOX";;56.97530225;100.0;100.0;;;Y;R;"6465411";"18716813";"18161412";"14057314";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42071;20200202;"NOX";;94.38573864;100.0;100.0;;;Y;R;"3864011";"37179913";"35429612";"13471814";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42071;20200202;"NOX";;74.45319571;100.0;100.0;;;Y;R;"3864011";"37179413";"35429412";"13472314";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42071;20200202;"NOX";;72.36193858;100.0;100.0;;;Y;R;"3864011";"37179813";"35429512";"13471914";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42071;20200202;"NOX";;78.17310176;100.0;100.0;;;Y;R;"3864011";"37180013";"35429912";"13471714";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42071;20200202;"NOX";;50.62294172;100.0;100.0;;;Y;R;"3864011";"37179713";"35429712";"13472014";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42071;20200202;"NOX";;69.77829237;100.0;100.0;;;Y;R;"3864011";"37179613";"35429812";"13472114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42099;20200201;"NOX";;54.76206671;100.0;100.0;;;Y;R;"3873111";"37779013";"36032412";"14323014";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42099;20200201;"NOX";;60.96826266;100.0;100.0;;;Y;R;"3873111";"37778913";"36032312";"14323114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42037;20200201;"NOX";;80.91493489;100.0;100.0;;;Y;R;"6602711";"19029113";"18490112";"16938914";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42081;20200201;"NOX";;78.69135339;100.0;100.0;;;Y;R;"5450911";"27549413";"26441112";"13858014";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42081;20200201;"NOX";;79.09780093;100.0;100.0;;;Y;R;"5450911";"27549313";"26441312";"13858114";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing Gas Turbine NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
42059;20200202;"NOX";;2.5084;100.0;100.0;;;Y;R;"3747111";"37859813";"62087512";"13846314";2023-01-01 00:00:00;! PA RACT II: CE is only valid when used with existing RICE NSPS controls.  RACT controls apply to existing sources & NSPS to new sources.  Source provided by PA DEP 7/8/16
/END/